paint·day

Is it good to coat in Long Beach, CA this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Long Beach, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayGood to goBest upcoming window: Sun (Good to go)
SunGO
70°/65°
Dew margin
5.2°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 65–70°F, RH under 81%, surface stays 5.2°F+ above the dew point, no rain in the cure window.

MonCAUTION
68°/64°
Dew margin
4.6°F
Overnight dew
Watch
Rain
5%
Window
8am–6pm

Watch overnight dew — surface comes within 4.6°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

TueGO
72°/65°
Dew margin
7.1°F
Overnight dew
Low
Rain
5%
Window
8am–5pm

Clear to coat: temps 65–72°F, RH under 66%, surface stays 7.1°F+ above the dew point, no rain in the cure window.

WedRISK
73°/65°
Dew margin
3.7°F
Overnight dew
High
Rain
4%
Window

High condensation risk overnight — surface dips to within 3.7°F of the 55°F dew point (low 59°F, 5% cloud, 4 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

ThuCAUTION
74°/66°
Dew margin
4.3°F
Overnight dew
Watch
Rain
0%
Window
8am–5pm

Watch overnight dew — surface comes within 4.3°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

FriRISK
77°/67°
Dew margin
2.9°F
Overnight dew
High
Rain
1%
Window

High condensation risk overnight — surface dips to within 2.9°F of the 57°F dew point (low 60°F, 0% cloud, 3 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

SatGO
80°/68°
Dew margin
7.7°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 68–80°F, RH under 67%, surface stays 7.7°F+ above the dew point, no rain in the cure window.

Good to goSun — today & tonight
  • Clear to coat: temps 65–70°F, RH under 81%, surface stays 5.2°F+ above the dew point, no rain in the cure window.

Good to go. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 5086°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert