Is it good to coat in Hartford, CT this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Hartford, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Thu (Good to go)
SunRISK
65°/59°
Dew margin
-0.7°F
Overnight dew
High
Rain
72%
Window
—

High condensation risk overnight — surface dips to within -0.7°F of the 60°F dew point (low 57°F, 100% cloud, 9 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

MonRISK
57°/56°
Dew margin
0.6°F
Overnight dew
High
Rain
88%
Window
—

High condensation risk overnight — surface dips to within 0.6°F of the 53°F dew point (low 54°F, 100% cloud, 3 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

TueRISK
69°/57°
Dew margin
-0.3°F
Overnight dew
High
Rain
3%
Window
—

High condensation risk overnight — surface dips to within -0.3°F of the 55°F dew point (low 54°F, 13% cloud, 2 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

WedRISK
74°/60°
Dew margin
0.4°F
Overnight dew
High
Rain
1%
Window
—

High condensation risk overnight — surface dips to within 0.4°F of the 58°F dew point (low 59°F, 100% cloud, 3 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

ThuGO
82°/64°
Dew margin
5.5°F
Overnight dew
Low
Rain
3%
Window
9am–5pm

Clear to coat: temps 64–82°F, RH under 84%, surface stays 5.5°F+ above the dew point, no rain in the cure window.

FriGO
79°/69°
Dew margin
9.6°F
Overnight dew
Low
Rain
15%
Window
8am–5pm

Clear to coat: temps 69–79°F, RH under 76%, surface stays 9.6°F+ above the dew point, no rain in the cure window.

SatGO
64°/50°
Dew margin
16.5°F
Overnight dew
Low
Rain
11%
Window
8am–5pm

Clear to coat: temps 50–64°F, RH under 52%, surface stays 16.5°F+ above the dew point, no rain in the cure window.

Hold offSun — today & tonight
  • High condensation risk overnight — surface dips to within -0.7°F of the 60°F dew point (low 57°F, 100% cloud, 9 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.
  • Rain likely in the 24h cure window (72% chance, ~51.7mm) — it can wash out or mar an uncured coat.
  • High humidity (94%, over the 85% mark) slows drying — keep an eye on the cure window.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→