paint·day

Is it good to coat in Columbia, MD this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Columbia, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Thu (Good to go)
SunRISK
62°/59°
Dew margin
2.3°F
Overnight dew
Watch
Rain
51%
Window
—

Rain likely in the 24h cure window (51% chance, ~3.3mm) — it can wash out or mar an uncured coat.

MonCAUTION
70°/61°
Dew margin
2.2°F
Overnight dew
Watch
Rain
3%
Window
11am–4pm

Watch overnight dew — surface comes within 2.2°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

TueRISK
74°/63°
Dew margin
-1.4°F
Overnight dew
High
Rain
1%
Window
—

High condensation risk overnight — surface dips to within -1.4°F of the 59°F dew point (low 56°F, 0% cloud, 2 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

WedCAUTION
81°/63°
Dew margin
2.3°F
Overnight dew
Watch
Rain
1%
Window
9am–5pm

Watch overnight dew — surface comes within 2.3°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

ThuGO
85°/64°
Dew margin
9.3°F
Overnight dew
Low
Rain
2%
Window
8am–5pm

Clear to coat: temps 64–85°F, RH under 75%, surface stays 9.3°F+ above the dew point, no rain in the cure window.

FriGO
83°/69°
Dew margin
7.5°F
Overnight dew
Low
Rain
14%
Window
8am–5pm

Clear to coat: temps 69–83°F, RH under 81%, surface stays 7.5°F+ above the dew point, no rain in the cure window.

SatGO
62°/55°
Dew margin
18.9°F
Overnight dew
Low
Rain
28%
Window
8am–5pm

Clear to coat: temps 55–62°F, RH under 55%, surface stays 18.9°F+ above the dew point, no rain in the cure window.

Hold offSun — today & tonight
  • Rain likely in the 24h cure window (51% chance, ~3.3mm) — it can wash out or mar an uncured coat.
  • Watch overnight dew — surface comes within 2.3°F of the dew point (margin is 5°F). Time the coat to dry well before evening.
  • High humidity (88%, over the 85% mark) slows drying — keep an eye on the cure window.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Columbia