paint·day

Is it good to coat in Albuquerque, NM this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Albuquerque, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayGood to goBest upcoming window: Sun (Good to go)
SunGO
83°/58°
Dew margin
9.6°F
Overnight dew
Low
Rain
2%
Window
8am–5pm

Clear to coat: temps 58–83°F, RH under 82%, surface stays 9.6°F+ above the dew point, no rain in the cure window.

MonRISK
85°/59°
Dew margin
0.8°F
Overnight dew
High
Rain
74%
Window
—

High condensation risk overnight — surface dips to within 0.8°F of the 60°F dew point (low 59°F, 100% cloud, 9 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

TueRISK
62°/59°
Dew margin
2.4°F
Overnight dew
Watch
Rain
92%
Window
—

Rain likely in the 24h cure window (92% chance, ~12.6mm) — it can wash out or mar an uncured coat.

WedRISK
60°/56°
Dew margin
2.6°F
Overnight dew
High
Rain
53%
Window
—

High condensation risk overnight — surface dips to within 2.6°F of the 49°F dew point (low 52°F, 0% cloud, 2 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

ThuGO
71°/59°
Dew margin
5°F
Overnight dew
Low
Rain
2%
Window
8am–5pm

Clear to coat: temps 59–71°F, RH under 67%, surface stays 5°F+ above the dew point, no rain in the cure window.

FriRISK
73°/58°
Dew margin
-0.5°F
Overnight dew
High
Rain
0%
Window
—

High condensation risk overnight — surface dips to within -0.5°F of the 46°F dew point (low 46°F, 0% cloud, 4 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

SatGO
76°/62°
Dew margin
12.1°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 62–76°F, RH under 57%, surface stays 12.1°F+ above the dew point, no rain in the cure window.

Good to goSun — today & tonight
  • Clear to coat: temps 58–83°F, RH under 82%, surface stays 9.6°F+ above the dew point, no rain in the cure window.

Good to go. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Albuquerque

Epoxy & Resin Floors weather elsewhere in New Mexico