paint·day

Is it good to coat in Reno, NV this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Reno, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayGood to goBest upcoming window: Sun (Good to go)
SunGO
70°/52°
Dew margin
23.3°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 52–70°F, RH under 48%, surface stays 23.3°F+ above the dew point, no rain in the cure window.

MonGO
79°/58°
Dew margin
19.6°F
Overnight dew
Low
Rain
3%
Window
8am–5pm

Clear to coat: temps 58–79°F, RH under 25%, surface stays 19.6°F+ above the dew point, no rain in the cure window.

TueGO
84°/64°
Dew margin
18.6°F
Overnight dew
Low
Rain
2%
Window
8am–5pm

Clear to coat: temps 64–84°F, RH under 26%, surface stays 18.6°F+ above the dew point, no rain in the cure window.

WedGO
84°/64°
Dew margin
20.2°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 64–84°F, RH under 26%, surface stays 20.2°F+ above the dew point, no rain in the cure window.

ThuGO
81°/65°
Dew margin
18.3°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 65–81°F, RH under 24%, surface stays 18.3°F+ above the dew point, no rain in the cure window.

FriGO
86°/65°
Dew margin
15.1°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 65–86°F, RH under 31%, surface stays 15.1°F+ above the dew point, no rain in the cure window.

SatRISK
94°/72°
Dew margin
28.6°F
Overnight dew
Low
Rain
0%
Window

Too hot — high of 94°F is well over the 86°F ceiling; the film skins over before it can level or adhere.

Good to goSun — today & tonight
  • Clear to coat: temps 52–70°F, RH under 48%, surface stays 23.3°F+ above the dew point, no rain in the cure window.

Good to go. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 5086°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert

Other coatings in Reno

Epoxy & Resin Floors weather elsewhere in Nevada