paint·day

Is it good to coat in Athens, GA this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Athens, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Wed (Caution)
SunRISK
57°/30°
Dew margin
-0.4°F
Overnight dew
High
Rain
0%
Window
—

High condensation risk overnight — surface dips to within -0.4°F of the 29°F dew point (low 28°F, 0% cloud, 5 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

MonRISK
58°/37°
Dew margin
3.4°F
Overnight dew
High
Rain
0%
Window
—

High condensation risk overnight — surface dips to within 3.4°F of the 31°F dew point (low 33°F, 0% cloud, 6 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

TueRISK
62°/36°
Dew margin
4.3°F
Overnight dew
High
Rain
0%
Window
—

High condensation risk overnight — surface dips to within 4.3°F of the 33°F dew point (low 37°F, 0% cloud, 6 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

WedCAUTION
64°/40°
Dew margin
7.3°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 40°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

ThuCAUTION
68°/44°
Dew margin
4.3°F
Overnight dew
Watch
Rain
0%
Window
9am–4pm

Watch overnight dew — surface comes within 4.3°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

FriRISK
67°/52°
Dew margin
0.4°F
Overnight dew
High
Rain
1%
Window
—

High condensation risk overnight — surface dips to within 0.4°F of the 45°F dew point (low 45°F, 100% cloud, 10 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

SatRISK
54°/51°
Dew margin
2.3°F
Overnight dew
Watch
Rain
3%
Window
—

Rain likely in the 24h cure window (3% chance, ~6.9mm) — it can wash out or mar an uncured coat.

Hold offSun — today & tonight
  • High condensation risk overnight — surface dips to within -0.4°F of the 29°F dew point (low 28°F, 0% cloud, 5 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.
  • Cold mornings (down to 30°F, floor is 50°F) — wait for the surface to warm past midday before you coat.
  • High humidity (94%, over the 85% mark) slows drying — keep an eye on the cure window.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Athens