paint·day

Is it good to coat in Macon, GA this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Macon, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Thu (Good to go)
SunRISK
59°/34°
Dew margin
-1.2°F
Overnight dew
High
Rain
0%
Window
—

High condensation risk overnight — surface dips to within -1.2°F of the 32°F dew point (low 31°F, 78% cloud, 4 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

MonCAUTION
61°/37°
Dew margin
8.1°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 37°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

TueCAUTION
65°/40°
Dew margin
9°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 40°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

WedCAUTION
68°/47°
Dew margin
5.2°F
Overnight dew
Low
Rain
0%
Window
9am–5pm

Cold mornings (down to 47°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

ThuGO
70°/51°
Dew margin
5°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 51–70°F, RH under 61%, surface stays 5°F+ above the dew point, no rain in the cure window.

FriGO
66°/58°
Dew margin
6°F
Overnight dew
Low
Rain
4%
Window
8am–5pm

Clear to coat: temps 58–66°F, RH under 61%, surface stays 6°F+ above the dew point, no rain in the cure window.

SatRISK
58°/55°
Dew margin
6.8°F
Overnight dew
Low
Rain
5%
Window
—

Rain likely in the 24h cure window (5% chance, ~2.1mm) — it can wash out or mar an uncured coat.

Hold offSun — today & tonight
  • High condensation risk overnight — surface dips to within -1.2°F of the 32°F dew point (low 31°F, 78% cloud, 4 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.
  • Cold mornings (down to 34°F, floor is 50°F) — wait for the surface to warm past midday before you coat.
  • High humidity (93%, over the 85% mark) slows drying — keep an eye on the cure window.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Macon

Epoxy & Resin Floors weather elsewhere in Georgia