Is it good to coat in Honolulu, HI this week?
A live 7-day go/no-go calendar for epoxy & resin floors in Honolulu, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.
- Dew margin
- 3.1°F
- Overnight dew
- Watch
- Rain
- 51%
- Window
- —
Rain likely in the 24h cure window (51% chance, ~1.1mm) — it can wash out or mar an uncured coat.
- Dew margin
- 3°F
- Overnight dew
- Watch
- Rain
- 49%
- Window
- —
Rain likely in the 24h cure window (49% chance, ~3mm) — it can wash out or mar an uncured coat.
- Dew margin
- 2.3°F
- Overnight dew
- Watch
- Rain
- 43%
- Window
- —
Rain likely in the 24h cure window (43% chance, ~2.2mm) — it can wash out or mar an uncured coat.
- Dew margin
- 1.3°F
- Overnight dew
- High
- Rain
- 20%
- Window
- —
High condensation risk overnight — surface dips to within 1.3°F of the 70°F dew point (low 72°F, 59% cloud, 9 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.
- Dew margin
- 2.2°F
- Overnight dew
- Watch
- Rain
- 25%
- Window
- —
Rain likely in the 24h cure window (25% chance, ~1.1mm) — it can wash out or mar an uncured coat.
- Dew margin
- 2.9°F
- Overnight dew
- Watch
- Rain
- 22%
- Window
- —
Rain likely in the 24h cure window (22% chance, ~2.4mm) — it can wash out or mar an uncured coat.
- Dew margin
- 3.6°F
- Overnight dew
- Watch
- Rain
- 17%
- Window
- —
Rain likely in the 24h cure window (17% chance, ~2.5mm) — it can wash out or mar an uncured coat.
- Rain likely in the 24h cure window (51% chance, ~1.1mm) — it can wash out or mar an uncured coat.
- Watch overnight dew — surface comes within 3.1°F of the dew point (margin is 5°F). Time the coat to dry well before evening.
Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.
Why these thresholds
Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.
- • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
- • Air + surface in the 50–86°F band (low-temp lines to 50°F).
- • Humidity under 85%; ideally under 80%.
- • No rain for 24h after application.
- • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.
Free in the beta
Watch this job site 24/7
Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.