paint·day

Is it good to coat in Idaho Falls, ID this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Idaho Falls, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayCautionBest upcoming window: Sun (Good to go)
ThuCAUTION
74°/44°
Dew margin
7.3°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 44°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

FriCAUTION
81°/41°
Dew margin
18°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 41°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

SatCAUTION
79°/43°
Dew margin
14.7°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 43°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

SunGO
84°/52°
Dew margin
17°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 52–84°F, RH under 31%, surface stays 17°F+ above the dew point, no rain in the cure window.

MonGO
83°/56°
Dew margin
10.2°F
Overnight dew
Low
Rain
2%
Window
8am–5pm

Clear to coat: temps 56–83°F, RH under 31%, surface stays 10.2°F+ above the dew point, no rain in the cure window.

TueGO
81°/58°
Dew margin
24.8°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 58–81°F, RH under 38%, surface stays 24.8°F+ above the dew point, no rain in the cure window.

WedGO
78°/53°
Dew margin
38.6°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 53–78°F, RH under 22%, surface stays 38.6°F+ above the dew point, no rain in the cure window.

CautionThu — today & tonight
  • Cold mornings (down to 44°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

Caution. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Idaho Falls