Is it good to stain in Annapolis, MD this week?
A live 7-day go/no-go calendar for deck & fence stain in Annapolis, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.
- Dew margin
- 6.6°F
- Overnight dew
- Low
- Rain
- 14%
- Window
- 8am–5pm
Clear to stain: temps 75–86°F, RH under 77%, surface stays 6.6°F+ above the dew point, no rain in the cure window.
- Dew margin
- 7°F
- Overnight dew
- Low
- Rain
- 10%
- Window
- 8am–5pm
Clear to stain: temps 76–90°F, RH under 74%, surface stays 7°F+ above the dew point, no rain in the cure window.
- Dew margin
- 4.3°F
- Overnight dew
- High
- Rain
- 33%
- Window
- —
High condensation risk overnight — surface dips to within 4.3°F of the 66°F dew point (low 69°F, 9% cloud, 6 mph wind). A fresh stain can blush/blister. Stop 4h before dew falls.
- Dew margin
- 3.5°F
- Overnight dew
- Watch
- Rain
- 12%
- Window
- 8am–5pm
Watch overnight dew — surface comes within 3.5°F of the dew point (margin is 5°F). Time the coat to dry well before evening.
- Dew margin
- 1.8°F
- Overnight dew
- High
- Rain
- 50%
- Window
- —
High condensation risk overnight — surface dips to within 1.8°F of the 72°F dew point (low 73°F, 83% cloud, 7 mph wind). A fresh stain can blush/blister. Stop 4h before dew falls.
- Dew margin
- 2.1°F
- Overnight dew
- Watch
- Rain
- 22%
- Window
- —
Rain likely in the 24h cure window (22% chance, ~9.9mm) — it can wash out or mar an uncured stain.
- Dew margin
- 9.3°F
- Overnight dew
- Low
- Rain
- 5%
- Window
- 8am–5pm
Clear to stain: temps 73–85°F, RH under 84%, surface stays 9.3°F+ above the dew point, no rain in the cure window.
- Clear to stain: temps 75–86°F, RH under 77%, surface stays 6.6°F+ above the dew point, no rain in the cure window.
Good to go. These are forecast numbers — confirm the surface temperature on-site before you start.
Why these thresholds
Stain applied to a damp or dew-wet board can't penetrate — it beads, stays tacky and flakes. Wood must be dry and stay above the dew point while it sets.
- • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
- • Air + surface in the 50–90°F band (low-temp lines to 45°F).
- • Humidity under 85%; ideally under 70%.
- • No rain for 24h after application.
- • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.
Free in the beta
Watch this job site 24/7
Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.