paint·day

Is it good to coat in Boulder, CO this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Boulder, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold off
TueRISK
94°/78°
Dew margin
27.2°F
Overnight dew
Low
Rain
14%
Window

Too hot — high of 94°F is well over the 86°F ceiling; the film skins over before it can level or adhere.

WedRISK
95°/72°
Dew margin
4.3°F
Overnight dew
Watch
Rain
29%
Window

Too hot — high of 95°F is well over the 86°F ceiling; the film skins over before it can level or adhere.

ThuRISK
85°/65°
Dew margin
2.4°F
Overnight dew
Watch
Rain
96%
Window

Rain likely in the 24h cure window (96% chance, ~26.3mm) — it can wash out or mar an uncured coat.

FriRISK
85°/69°
Dew margin
1.8°F
Overnight dew
High
Rain
94%
Window

High condensation risk overnight — surface dips to within 1.8°F of the 63°F dew point (low 62°F, 100% cloud, 12 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

SatRISK
86°/70°
Dew margin
9.6°F
Overnight dew
Low
Rain
76%
Window

Rain likely in the 24h cure window (76% chance, ~1.3mm) — it can wash out or mar an uncured coat.

SunRISK
84°/68°
Dew margin
1.4°F
Overnight dew
High
Rain
70%
Window

High condensation risk overnight — surface dips to within 1.4°F of the 58°F dew point (low 59°F, 96% cloud, 6 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

MonRISK
89°/70°
Dew margin
9.3°F
Overnight dew
Low
Rain
44%
Window

Rain likely in the 24h cure window (44% chance, ~9.9mm) — it can wash out or mar an uncured coat.

Hold offTue — today & tonight
  • Too hot — high of 94°F is well over the 86°F ceiling; the film skins over before it can level or adhere.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 5086°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert

Other coatings in Boulder

Epoxy & Resin Floors weather elsewhere in Colorado