paint·day

Is it good to coat in Fort Collins, CO this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Fort Collins, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Sat (Good to go)
ThuRISK
73°/53°
Dew margin
-1.2°F
Overnight dew
High
Rain
5%
Window
—

High condensation risk overnight — surface dips to within -1.2°F of the 45°F dew point (low 44°F, 74% cloud, 2 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

FriCAUTION
80°/49°
Dew margin
19.7°F
Overnight dew
Low
Rain
0%
Window
10am–5pm

Cold mornings (down to 49°F, floor is 50°F) — wait for the surface to warm past midday before you coat.

SatGO
85°/66°
Dew margin
5.1°F
Overnight dew
Low
Rain
0%
Window
8am–5pm

Clear to coat: temps 66–85°F, RH under 26%, surface stays 5.1°F+ above the dew point, no rain in the cure window.

SunGO
80°/56°
Dew margin
5.7°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 56–80°F, RH under 50%, surface stays 5.7°F+ above the dew point, no rain in the cure window.

MonCAUTION
88°/65°
Dew margin
19.7°F
Overnight dew
Low
Rain
3%
Window
8am–5pm

Hot afternoon (88°F, ceiling 86°F) — coat early and follow the shade.

TueGO
82°/70°
Dew margin
18.9°F
Overnight dew
Low
Rain
7%
Window
8am–5pm

Clear to coat: temps 70–82°F, RH under 27%, surface stays 18.9°F+ above the dew point, no rain in the cure window.

WedGO
84°/66°
Dew margin
23.4°F
Overnight dew
Low
Rain
1%
Window
8am–5pm

Clear to coat: temps 66–84°F, RH under 26%, surface stays 23.4°F+ above the dew point, no rain in the cure window.

Hold offThu — today & tonight
  • High condensation risk overnight — surface dips to within -1.2°F of the 45°F dew point (low 44°F, 74% cloud, 2 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 50–86°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert→

Other coatings in Fort Collins

Epoxy & Resin Floors weather elsewhere in Colorado