paint·day

Is it good to coat in Rochester, NY this week?

A live 7-day go/no-go calendar for epoxy & resin floors in Rochester, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.

TodayHold offBest upcoming window: Sat (Good to go)
ThuRISK
79°/68°
Dew margin
1.7°F
Overnight dew
High
Rain
3%
Window

High condensation risk overnight — surface dips to within 1.7°F of the 59°F dew point (low 59°F, 10% cloud, 6 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

FriRISK
79°/65°
Dew margin
0.3°F
Overnight dew
High
Rain
17%
Window

High condensation risk overnight — surface dips to within 0.3°F of the 61°F dew point (low 59°F, 99% cloud, 3 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

SatGO
83°/63°
Dew margin
5.1°F
Overnight dew
Low
Rain
25%
Window
8am–5pm

Clear to coat: temps 63–83°F, RH under 83%, surface stays 5.1°F+ above the dew point, no rain in the cure window.

SunRISK
81°/70°
Dew margin
2.5°F
Overnight dew
Watch
Rain
64%
Window

Rain likely in the 24h cure window (64% chance) — it can wash out or mar an uncured coat.

MonCAUTION
77°/68°
Dew margin
3.8°F
Overnight dew
Watch
Rain
14%
Window
8am–5pm

Watch overnight dew — surface comes within 3.8°F of the dew point (margin is 5°F). Time the coat to dry well before evening.

TueGO
81°/63°
Dew margin
7.2°F
Overnight dew
Low
Rain
4%
Window
8am–5pm

Clear to coat: temps 63–81°F, RH under 75%, surface stays 7.2°F+ above the dew point, no rain in the cure window.

WedRISK
78°/67°
Dew margin
1.5°F
Overnight dew
High
Rain
34%
Window

High condensation risk overnight — surface dips to within 1.5°F of the 64°F dew point (low 65°F, 0% cloud, 5 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.

Hold offThu — today & tonight
  • High condensation risk overnight — surface dips to within 1.7°F of the 59°F dew point (low 59°F, 10% cloud, 6 mph wind). A fresh coat can blush/blister. Stop 4h before dew falls.
  • High humidity (95%, over the 85% mark) slows drying — keep an eye on the cure window.

Hold off. These are forecast numbers — confirm the surface temperature on-site before you start.

Why these thresholds

Installing within 5°F of the dew point causes amine blush / carbamation — a cloudy, greasy, hazed floor. The slab surface temp, not the air, is what counts.

  • • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
  • • Air + surface in the 5086°F band (low-temp lines to 50°F).
  • • Humidity under 85%; ideally under 80%.
  • • No rain for 24h after application.
  • • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.

Free in the beta

Watch this job site 24/7

Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.

Set up a free alert

Other coatings in Rochester