Is it good to paint in El Paso, TX this week?
A live 7-day go/no-go calendar for exterior paint in El Paso, built from the local forecast against the 5°F-above-dew-point rule. We lead with the signal a weather app misses: overnight condensation risk.
- Dew margin
- 5.8°F
- Overnight dew
- Low
- Rain
- 4%
- Window
- 8am–5pm
Clear to paint: temps 59–79°F, RH under 83%, surface stays 5.8°F+ above the dew point, no rain in the cure window.
- Dew margin
- 3.7°F
- Overnight dew
- Watch
- Rain
- 7%
- Window
- 8am–5pm
Watch overnight dew — surface comes within 3.7°F of the dew point (margin is 5°F). Time the coat to dry well before evening.
- Dew margin
- 3.7°F
- Overnight dew
- Watch
- Rain
- 0%
- Window
- 8am–5pm
Watch overnight dew — surface comes within 3.7°F of the dew point (margin is 5°F). Time the coat to dry well before evening.
- Dew margin
- 6.4°F
- Overnight dew
- Low
- Rain
- 5%
- Window
- 8am–5pm
Clear to paint: temps 66–78°F, RH under 72%, surface stays 6.4°F+ above the dew point, no rain in the cure window.
- Dew margin
- 7.4°F
- Overnight dew
- Low
- Rain
- 3%
- Window
- 8am–5pm
Clear to paint: temps 68–81°F, RH under 69%, surface stays 7.4°F+ above the dew point, no rain in the cure window.
- Dew margin
- 10.1°F
- Overnight dew
- Low
- Rain
- 5%
- Window
- 8am–5pm
Clear to paint: temps 73–81°F, RH under 55%, surface stays 10.1°F+ above the dew point, no rain in the cure window.
- Dew margin
- 10.3°F
- Overnight dew
- Low
- Rain
- 5%
- Window
- —
Rain likely in the 24h cure window (5% chance, ~2.7mm) — it can wash out or mar an uncured paint.
- Clear to paint: temps 59–79°F, RH under 83%, surface stays 5.8°F+ above the dew point, no rain in the cure window.
Good to go. These are forecast numbers — confirm the surface temperature on-site before you start.
Why these thresholds
Overnight dew condensing on a fresh coat causes blistering, surfactant leaching and peeling — the cause of 40%+ of exterior paint failures.
- • Surface temp must stay 5°F above the dew point through application and cure (ASTM D3276 / ISO 8502-42).
- • Air + surface in the 50–85°F band (low-temp lines to 35°F).
- • Humidity under 85%; ideally under 70%.
- • No rain for 24h after application.
- • We use the forecast ground-surface temperature as a surface-temp proxy — confirm on-site with an IR thermometer.
Free in the beta
Watch this job site 24/7
Get an email the moment overnight dew, rain, or an out-of-range stretch threatens a fresh coat — and a morning digest with the best window ahead. No app to check; we watch the forecast for you.